{"id":7667,"date":"2026-11-09T02:23:53","date_gmt":"2026-11-09T02:23:53","guid":{"rendered":"https:\/\/www.chaoqian.com\/que-es-la-perdida-de-fibra-y-por-que-es-importante\/"},"modified":"2026-11-16T05:54:21","modified_gmt":"2026-11-16T05:54:21","slug":"que-es-la-perdida-de-fibra-y-por-que-es-importante","status":"publish","type":"post","link":"https:\/\/www.chaoqian.com\/es\/que-es-la-perdida-de-fibra-y-por-que-es-importante\/","title":{"rendered":"\u00bfQu\u00e9 es la p\u00e9rdida de fibra y por qu\u00e9 es importante?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Todos los proyectos de ingenier\u00eda deben tener en cuenta las p\u00e9rdidas y las tolerancias operativas, y las redes de fibra hasta el hogar (FTTH) no son una excepci\u00f3n. En las redes FTTH, esto se denomina p\u00e9rdida de fibra, o atenuaci\u00f3n, que se refiere a la reducci\u00f3n de la potencia \u00f3ptica a medida que la luz viaja a trav\u00e9s de la fibra \u00f3ptica y pasa por conexiones, divisores y otros componentes. En la pr\u00e1ctica de campo, la gesti\u00f3n de la atenuaci\u00f3n por p\u00e9rdida \u00f3ptica desempe\u00f1a un papel importante en el costo y la fiabilidad del despliegue de una red de banda ancha. Las p\u00e9rdidas de se\u00f1al se acumulan a lo largo de la transmisi\u00f3n, lo que determina hasta d\u00f3nde puede llegar una red de banda ancha y qu\u00e9 tan bien se conectan los suscriptores.<\/p>\n\n<p class=\"wp-block-paragraph\">En la selecci\u00f3n de productos, la p\u00e9rdida \u00f3ptica se expresa en decibelios (dB) y desempe\u00f1a un papel importante al comparar componentes \u00f3pticos pasivos. La p\u00e9rdida combinada de la red debe estar dentro del l\u00edmite del presupuesto de potencia \u00f3ptica, as\u00ed como dejar suficiente margen para la instalaci\u00f3n, los cambios ambientales y el mantenimiento futuro. Esta publicaci\u00f3n de blog explicar\u00e1 en detalle la p\u00e9rdida de fibra, sus causas y sus aplicaciones pr\u00e1cticas, para proporcionar a los lectores los antecedentes necesarios para tomar decisiones informadas.<\/p>\n\n<h5 class=\"wp-block-heading\"><strong>CONOCIMIENTOS B\u00c1SICOS: ENTENDER dB, dBm Y dB\/km<\/strong><strong><\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">Antes de profundizar en las especificaciones del producto, es crucial distinguir estos t\u00e9rminos. Hay 4 unidades relevantes:<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>mW (milivatio): mide la potencia \u00f3ptica en una escala lineal. Un milivatio equivale a una mil\u00e9sima de vatio (=0,001 W); duplicar el valor en mW significa duplicar la potencia \u00f3ptica.<\/strong><\/li>\n\n\n\n<li><strong>dB (decibelio): expresa la relaci\u00f3n entre dos niveles de potencia en una escala logar\u00edtmica. En los c\u00e1lculos de p\u00e9rdida, compara la potencia que entra en una fibra o componente con la potencia que sale de \u00e9l.<\/strong><\/li>\n\n\n\n<li><strong>dBm<\/strong>: expresses optical power relative to a fixed reference of 1 mW. Like mW, it tells how much power is present &#8211; not the amount that has been lost.<\/li>\n\n\n\n<li><strong>dB\/m: expresa la atenuaci\u00f3n por metro de fibra a una determinada longitud de onda. Para proyectos de telecomunicaciones y FTTH, se utiliza ampliamente dB\/km.<\/strong><\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">En resumen, mW y dBm describen un nivel de potencia; dB describe una relaci\u00f3n de potencia relativa; y dB\/m o dB\/km describen la atenuaci\u00f3n por unidad de longitud.<\/p>\n\n<p class=\"wp-block-paragraph\">Pero \u00bfpor qu\u00e9 utilizamos dB, un t\u00e9rmino relativo, en lugar de mW? S\u00ed, la p\u00e9rdida de potencia puede expresarse y calcularse directamente en mW, pero cuando se trata de p\u00e9rdida \u00f3ptica, la cantidad no es un n\u00famero fijo destacado, sino que depende de la potencia de entrada. Cuanto m\u00e1s recibe, m\u00e1s pierde, como una \u201ctasa impositiva\u201d que se aplica a la luz que pasa a trav\u00e9s. Por ejemplo, considere una reducci\u00f3n de se\u00f1al de 2 mW a 1 mW: elimina 1 mW, mientras que una reducci\u00f3n de 0,2 mW a 0,1 mW elimina solo 0,1 mW; sin embargo, ambas representan el mismo cambio proporcional: se pierde la mitad de la se\u00f1al de entrada.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power-1024x576.png\" alt=\"\" class=\"wp-image-7625\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power-1024x576.png 1024w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power-300x169.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power-150x84.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power-768x432.png 768w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-different-units-used-in-measuring-optical-power.png 1063w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">En la ecuaci\u00f3n matem\u00e1tica, primero definimos la fracci\u00f3n de potencia despu\u00e9s de la transmisi\u00f3n como \u201cT\u201d:<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"163\" height=\"91\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-14.png\" alt=\"\" class=\"wp-image-7627\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-14.png 163w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-14-150x84.png 150w\" sizes=\"(max-width: 163px) 100vw, 163px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Por lo tanto, la p\u00e9rdida correspondiente en decibelios se define como:<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"533\" height=\"84\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-15.png\" alt=\"\" class=\"wp-image-7628\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-15.png 533w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-15-150x24.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-15-300x47.png 300w\" sizes=\"(max-width: 533px) 100vw, 533px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Aqu\u00ed, la entrada y la salida deben utilizar la misma unidad lineal, como mW, y el factor de 10 convierte la relaci\u00f3n de potencia logar\u00edtmica de base 10 en decibelios. Algunos puntos de referencia com\u00fanmente utilizados son:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>P\u00e9rdida de 0 dB: la entrada es exactamente igual a la salida, sin ninguna p\u00e9rdida.<\/li>\n\n\n\n<li>P\u00e9rdida de 3 dB: queda la mitad de la entrada.<\/li>\n\n\n\n<li>P\u00e9rdida de 10 dB: solo queda una d\u00e9cima parte.<\/li>\n\n\n\n<li>P\u00e9rdida de 20 dB: solo queda el 1 %.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">Si hay dos componentes pasivos consecutivos, la salida del primer componente se convierte autom\u00e1ticamente en la entrada del siguiente, por lo que sus fracciones de retenci\u00f3n de potencia se multiplican. No se necesita ninguna acci\u00f3n adicional; simplemente sumando las p\u00e9rdidas se obtiene la p\u00e9rdida total:<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"771\" height=\"59\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-16.png\" alt=\"\" class=\"wp-image-7629\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-16.png 771w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-16-150x11.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-16-300x23.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-16-758x58.png 758w\" sizes=\"(max-width: 771px) 100vw, 771px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Mientras que dB compara dos niveles relativos de potencia, dBm fija el denominador en 1 mW, lo que permite expresar un nivel de potencia concreto en forma logar\u00edtmica:<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"283\" height=\"145\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-17.png\" alt=\"\" class=\"wp-image-7630\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-17.png 283w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-17-150x77.png 150w\" sizes=\"(max-width: 283px) 100vw, 283px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Aqu\u00ed, un dBm negativo no significa una potencia \u00f3ptica negativa, sino que la potencia real est\u00e1 por debajo de 1 mW. A la inversa, 0 dBm no significa que no haya luz, sino que la potencia es exactamente igual a 1 mW. Algunas referencias de uso com\u00fan son:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>+10 dBm = 10 mW<\/li>\n\n\n\n<li>0 dBm = 1 mW<\/li>\n\n\n\n<li>-10 dBm = 0.1 mW<\/li>\n\n\n\n<li>-20 dBm = 0.01 mW<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">En la pr\u00e1ctica, existen cuatro operaciones comunes de p\u00e9rdida de fibra:<\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"898\" height=\"143\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-20.png\" alt=\"\" class=\"wp-image-7633\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-20.png 898w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-20-300x48.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-20-150x24.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-20-766x122.png 766w\" sizes=\"(max-width: 898px) 100vw, 898px\" \/><\/figure>\n\n<h5 class=\"wp-block-heading\">\u00bfQU\u00c9 CAUSA LA P\u00c9RDIDA \u00d3PTICA?<\/h5>\n\n<p class=\"wp-block-paragraph\">La potencia \u00f3ptica disminuye a medida que la luz viaja a trav\u00e9s de la fibra, atraviesa conexiones y pasa por divisores. Parte de esta p\u00e9rdida es esperada, mientras que una instalaci\u00f3n o manipulaci\u00f3n deficiente puede ejercer una p\u00e9rdida adicional.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Absorci\u00f3n y dispersi\u00f3n del material: incluso una fibra limpia y sin da\u00f1os pierde algo de potencia \u00f3ptica durante la transmisi\u00f3n debido a la absorci\u00f3n y la dispersi\u00f3n. La absorci\u00f3n ocurre cuando el vidrio y las impurezas presentes en \u00e9l absorben energ\u00eda \u00f3ptica; la dispersi\u00f3n redirige parte de la luz fuera de su trayectoria hacia adelante, en parte debido a variaciones microsc\u00f3picas del material en el vidrio. Estos efectos se acumulan con la distancia, por lo que una fibra m\u00e1s larga generalmente introduce m\u00e1s p\u00e9rdida a la misma longitud de onda. La atenuaci\u00f3n tambi\u00e9n var\u00eda con la longitud de onda, por lo que la especificaci\u00f3n de una fibra debe indicar tanto el coeficiente de atenuaci\u00f3n en dB\/km como la longitud de onda a la que se aplica.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Bending &amp; Mechanical Stress<\/strong>: Fiber can also lose power when it is bent too tightly or subjected to pressure. There are two forms of bending are worth distinguishing:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>La macrocurvatura es una curvatura a mayor escala, como un bucle apretado o un giro pronunciado; una curvatura excesiva permite que m\u00e1s luz escape de la trayectoria guiada.<\/li>\n\n\n\n<li>La microcurvatura implica distorsiones diminutas y m\u00ednimas, a menudo causadas por presi\u00f3n o tensi\u00f3n mec\u00e1nica, y puede no ser visible desde el exterior del cable.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\"><strong>Conexiones y empalmes: los componentes de conexi\u00f3n permiten que la se\u00f1al luminosa pase de una fibra a otra, y parte de la potencia puede perderse en la uni\u00f3n. En los conectores, el polvo, el aceite, los ara\u00f1azos o un acoplamiento deficiente pueden aumentar la p\u00e9rdida, por lo que la inspecci\u00f3n y limpieza de la cara final son importantes antes de la conexi\u00f3n. En los empalmes por fusi\u00f3n, la calidad de la preparaci\u00f3n de la fibra, la alineaci\u00f3n y el proceso de fusi\u00f3n afectan el resultado.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Divisi\u00f3n \u00f3ptica: un divisor distribuye proporcionalmente la potencia disponible a cada salida. A diferencia de la curvatura o la contaminaci\u00f3n ambiental, la divisi\u00f3n provoca una reducci\u00f3n intencionada de la potencia en la red PON, que est\u00e1 dise\u00f1ada para distribuir la se\u00f1al desde el puerto OLT hacia m\u00faltiples suscriptores.<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Para un divisor ideal de relaci\u00f3n uniforme, una divisi\u00f3n 1:16 entrega a cada salida una dieciseisava parte de la potencia de entrada, aproximadamente 12 dB de p\u00e9rdida por salida; mientras que una divisi\u00f3n 1:32 proporciona aproximadamente 15 dB.<\/li>\n<\/ul>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss-1024x576.png\" alt=\"\" class=\"wp-image-7634\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss-1024x576.png 1024w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss-150x84.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss-300x169.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss-768x432.png 768w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-detailed-explanation-on-four-causes-of-optical-loss.png 1082w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">En la pr\u00e1ctica, los divisores PLC probablemente presentan una p\u00e9rdida adicional m\u00e1s all\u00e1 de su divisi\u00f3n de potencia dise\u00f1ada, por lo que los c\u00e1lculos deben sumar la p\u00e9rdida de inserci\u00f3n especificada del producto al valor te\u00f3rico. Una mayor relaci\u00f3n de divisi\u00f3n deja menos potencia \u00f3ptica para cada suscriptor, lo que hace que la selecci\u00f3n del divisor sea un equilibrio entre el n\u00famero de ramificaciones y la p\u00e9rdida que el enlace puede tolerar. Sin embargo, en el extremo del suscriptor, los m\u00f3dems ONT\/ONU tambi\u00e9n tienen un umbral sobre la potencia \u00f3ptica m\u00e1xima que reciben. En algunos casos peculiares, los t\u00e9cnicos de FTTH incluso instalan un atenuador \u00f3ptico para reducir la se\u00f1al.<\/p>\n\n<h5 class=\"wp-block-heading\"><strong>EL PRESUPUESTO Y EL COSTO<\/strong><strong><\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">La p\u00e9rdida de inserci\u00f3n, por s\u00ed sola, no convierte a un producto en la mejor opci\u00f3n. Lo que m\u00e1s importa es si todo el trayecto \u00f3ptico pasivo funciona en conjunto dentro de los l\u00edmites de potencia requeridos. En una red GPON, el terminal de l\u00ednea \u00f3ptica (OLT) env\u00eda se\u00f1ales de bajada hacia los suscriptores a una longitud de onda de aproximadamente 1490 nm. Para la Clase B+, su potencia de lanzamiento media especificada es de +1,5 a +5 dBm; la Clase C+ ampl\u00eda este rango a +3 a +7 dBm. En el hogar del suscriptor, el terminal de red \u00f3ptica (ONT\/ONU) debe recibir suficiente potencia para recuperar la se\u00f1al sin sobrecargarse. Para una ONT de Clase B+, la norma especifica una sensibilidad del receptor de -27 dBm y un nivel de sobrecarga de -8 dBm, lo que proporciona una ventana \u00fatil de recepci\u00f3n de referencia de \u221227 a -8 dBm. Aqu\u00ed, la sensibilidad del receptor se refiere al l\u00edmite de se\u00f1al m\u00e1s d\u00e9bil en las condiciones de prueba, no a un objetivo operativo recomendado. En t\u00e9rminos de presupuesto de potencia, para una red GPON, la ventana de p\u00e9rdida de la ODN (el presupuesto total) var\u00eda de 13 a 28 dB para la Clase B+ y de 17 a 32 dB para la Clase C+.<\/p>\n\n<p class=\"wp-block-paragraph\">Como se mencion\u00f3 en los p\u00e1rrafos anteriores, la p\u00e9rdida total consta de cuatro componentes: la fibra, los dispositivos, la divisi\u00f3n y el entorno. La fibra \u00f3ptica, por ejemplo, puede tener una atenuaci\u00f3n m\u00e1xima de 0,34 dB\/km a 1310 nm, 0,25 dB\/km a 1490 nm y 0,22 dB\/km a 1550 nm. En nuestro caso, podemos suponer que la distancia de la red es de 20 km. La p\u00e9rdida dentro de los equipos pasivos, como un distribuidor (distribution hub) o un cierre de empalme, puede ser de 0,4 dB por conexi\u00f3n (empalme por fusi\u00f3n + conexi\u00f3n). En cuanto a la divisi\u00f3n, un divisor de 1\u00d764 puede tener una p\u00e9rdida de inserci\u00f3n de 20 dB. Sumando todas las p\u00e9rdidas mencionadas anteriormente, obtendr\u00edamos la p\u00e9rdida total:<\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"896\" height=\"114\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-21.png\" alt=\"\" class=\"wp-image-7635\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-21.png 896w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-21-150x19.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-21-762x97.png 762w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/image-21-300x38.png 300w\" sizes=\"(max-width: 896px) 100vw, 896px\" \/><\/figure>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path-1024x576.png\" alt=\"\" class=\"wp-image-7636\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path-1024x576.png 1024w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path-300x169.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path-150x84.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path-768x432.png 768w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/a-graph-on-how-the-optical-loss-accumulate-along-the-path.png 1036w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Al comparar y seleccionar productos de equipos pasivos, la pregunta \u00fatil no es simplemente \u201c\u00bfcu\u00e1l tiene la menor p\u00e9rdida?\u201d, sino \u201c\u00bfqu\u00e9 producto garantiza el rendimiento requerido en condiciones comparables?\u201d. El valor t\u00edpico de un divisor, su valor m\u00e1ximo y la p\u00e9rdida medida de entrada a salida de un terminal describen cosas diferentes:<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>Configuraci\u00f3n: compare la misma relaci\u00f3n de divisi\u00f3n, el n\u00famero de etapas y la disposici\u00f3n de conexi\u00f3n, ya que un m\u00f3dulo de 1\u00d716 nunca puede compararse con un terminal de 1\u00d732.<\/strong><\/li>\n\n\n\n<li><strong>L\u00edmite de medici\u00f3n: confirme si la cifra incluye las conexiones de entrada y salida, los pigtails, los empalmes internos y cualquier otro componente en la ruta especificada; de lo contrario, se pueden omitir elementos o contarlos dos veces.<\/strong><\/li>\n\n\n\n<li><strong>M\u00e1ximo garantizado: utilice el m\u00e1ximo especificado para una verificaci\u00f3n de dise\u00f1o conservadora, en lugar de suponer que cada unidad y cada salida coincidir\u00e1n con la cifra t\u00edpica.<\/strong><\/li>\n\n\n\n<li><strong>Longitudes de onda y salidas: verifique el rendimiento en las longitudes de onda requeridas y en todos los puertos de salida relevantes, incluido el puerto de peor rendimiento y no solo un promedio.<\/strong><\/li>\n\n\n\n<li><strong>P\u00e9rdida de inserci\u00f3n frente a p\u00e9rdida de retorno: una menor p\u00e9rdida de inserci\u00f3n significa que se pierde menos potencia directa; una mayor p\u00e9rdida de retorno positiva significa que se refleja menos potencia. Una especificaci\u00f3n de p\u00e9rdida de retorno de 55 dB no significa que el producto consuma 55 dB de potencia de transmisi\u00f3n.<\/strong><\/li>\n\n\n\n<li><strong>Fiabilidad de instalaci\u00f3n: revise el control del radio de curvatura, el alivio de tensi\u00f3n, el sellado y el acceso para mantenimiento junto con los valores \u00f3pticos, porque la carcasa ayuda a proteger el rendimiento de los componentes que contiene.<\/strong><\/li>\n<\/ol>\n\n<h5 class=\"wp-block-heading\"><strong>C\u00d3MO CQT PUEDE AYUDAR A SU PROYECTO<\/strong><strong><\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">Zhejiang Chaoqian Communication Technology (CQT) suministra el hardware pasivo utilizado en las redes FTTH, incluidos cierres de empalme, cajas de distribuci\u00f3n, cajas de terminaci\u00f3n, cables \u00f3pticos y conectores. Adem\u00e1s de los productos convencionales, ofrecemos opciones preconnectorizadas que reducen la necesidad de empalmes por fusi\u00f3n en campo. Incluso si un modelo est\u00e1ndar no se adapta a su proyecto, podemos personalizarlo para realizar cambios sustanciales, con costos y plazos de entrega acordados antes de la producci\u00f3n.<\/p>\n\n<p class=\"wp-block-paragraph\">Nuestras capacidades est\u00e1n respaldadas por m\u00e1s de 70.000 m\u00b2 de instalaciones de fabricaci\u00f3n, con fabricaci\u00f3n de moldes propia, moldeo por inyecci\u00f3n, fabricaci\u00f3n de chapa met\u00e1lica y ensamblaje. Nuestro laboratorio acreditado por CNAS ofrece pruebas de p\u00e9rdida de inserci\u00f3n y p\u00e9rdida de retorno, junto con pruebas mec\u00e1nicas, de sellado, de ciclado t\u00e9rmico y de envejecimiento. Esto nos permite evaluar tanto el rendimiento \u00f3ptico como la capacidad del producto para proteger las conexiones en su interior.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team-1024x576.png\" alt=\"\" class=\"wp-image-7638\" srcset=\"https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team-1024x576.png 1024w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team-150x84.png 150w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team-300x169.png 300w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team-767x432.png 767w, https:\/\/www.chaoqian.com\/wp-content\/uploads\/CQTs-capabilities-are-backed-by-its-manufacture-experience-CNAS-accredited-laboratory-and-professional-customer-support-team.png 1096w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Nuestro soporte al cliente contin\u00faa despu\u00e9s de la entrega. Si se confirma un problema de calidad del producto, se pueden organizar de inmediato piezas de repuesto u otras soluciones. Para hablar sobre su proyecto, no dude en enviarnos la capacidad requerida, la configuraci\u00f3n del divisor, el tipo de conector, el entorno de instalaci\u00f3n y los requisitos de p\u00e9rdida \u00f3ptica, para que nuestro equipo pueda ofrecerle una soluci\u00f3n viable.<\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Todos los proyectos de ingenier\u00eda deben tener en cuenta las p\u00e9rdidas y las tolerancias operativas, y las redes de fibra hasta el hogar (FTTH) no son una excepci\u00f3n. En las redes FTTH, esto se denomina p\u00e9rdida de fibra, o atenuaci\u00f3n, que se refiere a la reducci\u00f3n de la potencia \u00f3ptica a medida que la luz [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7661,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[68],"tags":[154,155,135,150,151,152,153],"class_list":["post-7667","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","tag-fibra","tag-banda-ancha","tag-cqt","tag-ftth","tag-fibra-optica","tag-odn","tag-chaoqiantech"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/posts\/7667","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/comments?post=7667"}],"version-history":[{"count":1,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/posts\/7667\/revisions"}],"predecessor-version":[{"id":7671,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/posts\/7667\/revisions\/7671"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/media\/7661"}],"wp:attachment":[{"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/media?parent=7667"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/categories?post=7667"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.chaoqian.com\/es\/wp-json\/wp\/v2\/tags?post=7667"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}